Rheem Tankless Code 13: Why the Unit Shut Down and What to Check

Updated

Rheem tankless water heater code 13 means the unit shut itself down because it could not correct a combustion problem. Rheem's troubleshooting manual ties the code to the oxygen depletion sensor. Check that the air intake and outdoor vent are clear, reset once, and call a licensed gas technician if the code returns.

Figures checked September 2026. Code meanings from Rheem's use and care and troubleshooting documents; costs from dated sources listed at the end.

Cause, following Rheem's troubleshooting pageWhat gets checkedDIY or proTypical cost (source, date)
Not enough fresh combustion air, such as a tight closetRoom openings, closet door, intake clearanceDIY to spot, pro to fixVaries with the fix
Manifold gas pressure offPressure confirmed and adjustedPro, gas-qualifiedService call plus labor (see cost table)
Dirt or blockage in the heat exchanger or ventingVent run and exchanger finsPro$50 to $125 vent repair (Fixr, Jan. 2025)
Dirt on the fan motor or the air intake on the front coverFan and intake screenPro$50 to $400 maintenance visit (Fixr, Jan. 2025)
Blocked flame opening on the sensing burnerWhole burner assembly cleanedProPart of a service visit
Sensor reading low after the checks aboveUpper burner assembly replacedPro$400 to $800 burner (HomeGuide, July 2025)

What does the Rheem tankless water heater code 13 mean?

Code 13 is a safety shutdown after poor combustion that the unit could not fix on its own. Rheem's Tankless Troubleshooting Manual, page 50, describes it as the oxygen depletion sensor being activated because the unit "was not able to resolve an imperfect combustion issue." It is not a simple ignition failure.

The owner-facing chart says much less. In Rheem's Classic Plus use and care manual (AP18000-2 Rev 03, Service Error Code Chart, page 26, page images here), the cause column for 13 reads "If this code is still displayed after taking the numbered steps above," and the solution is to contact a dealer or qualified service technician. The numbered steps it refers to are the reset sequence on page 25.

TanklessHeaterHelp's generic code 13 page calls it a flame failure during operation. Rheem's page does not: the burner can be lit, and the sensor judges the combustion poor.

Which Rheem tankless models show code 13?

Code 13 appears on the Classic Plus chart and not on Rheem's current Eagle or condensing charts. A code 13 on your display is a strong sign you own one of the older noncondensing units, so use that manual, not a newer chart, when you look up the fix.

Product lineManual (form, page)Code 13 listed?Nearby air or vent code
Classic Plus noncondensingAP18000-2 Rev 03, p. 26Yes05: air intake or vent exhaust may be blocked
Eagle noncondensingAP22009 Rev 04, p. 77No90 or 99: air intake or vent blocked
IKONIC condensingAP22745 Rev 04, p. 93No (no A013)A090: air intake or vent blocked

The Classic Plus manual covers 199,900, 180,000 and 150,000 Btu/h noncondensing models, per its cover, and the manual host files it under RTG-64DVLN-1 and RTG-84DVLN-1. The Eagle manual and condensing manual charts were checked line by line. The rating label settles which chart applies.

Code 05 is the warning; code 13 is the shutdown. On the Classic Plus chart, 05 means the air intake or vent exhaust may be blocked, or the vent pipes may not be connected properly. Rheem's troubleshooting page describes 05 as the step where the board tries to correct the problem itself before it gives up with 13.

That same page, in Rheem's Tankless Troubleshooting Manual, flags one exception. If the sensor produces too little voltage, the board never senses the fault, never tries 05, and simply shuts down. If you saw 05 before 13, the air and vent path is the first place to look.

How do I clear code 13 on a Rheem tankless heater?

Close the hot taps, power the unit off at the remote, wait about 5 minutes, and restart. If 13 returns, unplug the unit for about 30 seconds and try once more. Rheem's chart then says to stop and call a technician, not to keep resetting a combustion fault.

  1. Turn off all hot water faucets.
  2. Press POWER ON/OFF on the remote and wait about five minutes.
  3. While you wait, look at the outdoor vent terminal for snow, leaves or nests, and check that nothing sits within 12 inches of the air intake.
  4. Press POWER again, open a hot faucet and watch the display.
  5. If 13 shows again, switch off, unplug for about 30 seconds, plug back in and retry once.
  6. If it still shows, turn the heater off, write down the code and call for service.

The reset sequence is on page 25 of the Classic Plus manual, and the 12-inch intake clearance and intake and vent check are on page 17 of the same AP18000-2 manual.

What does a technician check for code 13?

Fresh air and maintenance history first, then the sensor voltage, then gas pressure, then cleaning and parts. Rheem's troubleshooting page 50 runs as a short flowchart, and a technician only replaces the burner assembly after the other branches check out.

  1. Look for a lack of fresh combustion air, such as a unit in a tight closet.
  2. Review the maintenance history for earlier code 13 events.
  3. Measure the sensor thermocouple voltage at connector Q, red and white wires. Rheem's target is 8 to 30 mV DC. If it reads in range, the heater is treated as normal and run again.
  4. If the reading is low, check burner manifold gas pressure and adjust it if needed, using page 39 of that manual.
  5. If pressure is normal, clean dirt or blockage from the heat exchanger, venting, fan motor and front-cover air intake.
  6. Clear the sensing burner's flame opening and clean the whole burner assembly.
  7. If the fault persists, disconnect the thermocouple, replace the upper burner assembly and reconnect firmly.
  8. For a code 13 with no obvious cause, check the sensor wire to the control board (a loose wire reads zero in maintenance mode) and watch for a shutdown at exactly 2.5 minutes with no 05 first, which Rheem links to a missing sensor damper.

These steps paraphrase page 50 of Rheem's Tankless Troubleshooting Manual. They require the cover off and live power, which is why the owner's manual routes code 13 to a technician.

Was my Rheem tankless part of a recall?

Some older units were. The CPSC announced a recall on February 21, 2007 of about 42,200 tankless heaters sold under the Paloma, Rheem, Ruud, Rheem-Ruud and Richmond names, including model RTG-74PVN. A shifted air filter door switch could let dust and lint build up, posing a carbon monoxide hazard.

That is the same air-supply path code 13 guards. If your rating label shows a model on the CPSC list, the notice told owners to stop using the heater if the air filter door is not in place and to contact their installer or Rheem for a free on-site repair. The notice is from 2007; confirm with Rheem whether your serial number was already repaired.

Safety: code 13 is a carbon monoxide warning

Rheem's Classic Plus manual (page 19) warns that skipped maintenance can cause carbon monoxide dangers, tells owners not to run the heater if something seems wrong, and assigns burner, air intake filter and vent inspection to a qualified technician. Page 25 tells owners not to repair gas piping, burners, vent connectors or safety devices. Leave the unit off after a repeat code 13 and call a licensed gas technician. If you smell gas, leave the building and call the gas supplier from a neighbor's phone, as the manual's cover says. Venting basics for gas units are on the gas water heater repair guide.

What does a code 13 repair cost?

A cleaning and vent visit sits at the low end; a burner, board or heat exchanger sits at the high end. Fixr (January 2025) lists tankless vent repairs at $50 to $125, and HomeGuide (July 2025) lists a burner replacement at $400 to $800.

WorkRangeSource
Service call-out fee$50 to $200HomeGuide, August 2025
Plumber labor$45 to $150 per hourHomeGuide, August 2025
Professional maintenance visit$50 to $400Fixr, January 2025
Vent repair, labor included$50 to $125Fixr, January 2025
Vent replacement, labor included$75 to $250Fixr, January 2025
Burner replacement$400 to $800HomeGuide, July 2025
Circuit board replacement$400 to $800HomeGuide, July 2025
Heat exchanger replacement$600 to $1,300HomeGuide, July 2025

No dated price for Rheem's upper burner assembly or its oxygen depletion sensor could be confirmed for this guide, so treat the burner row as a general figure. The tankless maintenance cost guide covers what an annual service visit includes.

Is code 13 covered by Rheem's warranty?

A defective part may be; a venting or maintenance problem is not. Rheem's residential gas tankless warranty, form TKW-101 (January 2013) covers component parts for 5 years, labor for 1 year and the heat exchanger for 12 years on a single-family home.

Several exclusions in that document line up with code 13 causes:

  • Performance problems caused by improper sizing of the gas line, venting connection or combustion air openings.
  • Damage from improper installation, or from failing to maintain the unit per Rheem's instructions.
  • Heat exchanger leaks caused by a corrosive or contaminated atmosphere.

If there is no proof of the install date, the warranty status is based on the manufacture date from the serial number plus 90 days, per the same warranty form. Terms can differ by model; the certificate in your manual governs. The Rheem water heater repair guide lists warranty terms by product line.

Should you repair or replace after code 13?

Repair when the cause is air, venting or a cleanable burner; price a replacement when the heat exchanger or several major parts are failing. HomeGuide (August 2025) puts tankless lifespan at 10 to 20 years, and code 13 only appears on Rheem's older noncondensing chart.

SituationBetter moveWhy
Code 13 cleared after a blocked vent or closet door was fixedKeep the unit, schedule serviceThe cause was external
Dirty burner or fan, first code 13 in yearsClean and serviceRheem's check list starts with cleaning
Sensor or burner assembly failed, unit inside the 5-year parts termRepair under warrantyPart may be covered; labor term is 1 year
Code 13 plus a leaking or sooted heat exchanger on an old unitPrice a replacementSee the tankless replacement cost guide

For ignition and flame codes on newer models, see the Rheem tankless ignition code guide.

Frequently asked questions

Is code 13 the same as Rheem code 11 or 12?

No. On Rheem's charts, 11 and 12 point at the gas supply. Code 13 is a combustion-quality shutdown. The Rheem tankless code 11 guide covers code 11.

Can I clean the air filter myself?

Rheem's Classic Plus manual lists the air intake filter under professional preventive maintenance. The owner steps are keeping the intake clear and checking the intake and vent outlet for debris.

Why does code 13 come back after a reset?

A reset does not fix the cause. Rheem's troubleshooting page asks technicians to check maintenance history, because repeat events usually trace to air supply, dirt or a failing sensor.