Home > Guides > Rinnai Code 79: What the Leak Sensor Is Telling You

Rinnai Code 79: What the Leak Sensor Is Telling You

Updated

Rinnai code 79 means "Water Leakage Detected": the leak sensor at the bottom of the cabinet is wet, or its wiring is faulty. Turn off power, gas and water, then look for drips, pooled water and damp fittings. Condensation can set it off without a real leak, but only a technician should open the cabinet.

Figures checked September 2026. Code meanings from Rinnai's service documents; costs from dated sources listed below.

Cause, in Rinnai's orderWhat it looks likeWho handles it
Loose, broken or damaged wiring at the leak detectorCode with a dry cabinetTechnician
Leak from the heat exchanger or internal pipingWater inside, drips under the unitTechnician
Water pooled in the bottom pan with no leak foundDamp cabinet, often in humid or wet weatherTechnician dries it; see TB-101 below
Failed sensorUnit fires with the sensor unplugged during a testTechnician replaces sensor and screw
Optional drain-pan float switch lifted (RE and REP indoor models)Water in the pan under the unitOwner checks the pan, technician finds the source

Sources: steps 1-4 from Rinnai, Troubleshooting Tankless Water Heater Diagnostic Codes, p. 62, May 2024; float switch from Rinnai, Non-Condensing Leak Detection Kit instructions, February 2022.

What is error code 79 on a Rinnai tankless heater?

Code 79 is Rinnai's water leakage code. A sensor mounted low in the cabinet reports moisture, and the controller displays 79. The sensor cannot tell a failed heat exchanger from a film of condensation, so the code says water is present, not where it came from.

Rinnai titles the code "Water Leakage Detected" on page 62 of its diagnostic code guide, document 100000652. Its leak kit instructions quote the owner's manual wording as "Water Leak Detected."

Two pages ranking for this query get it wrong. One installer's code list labels 79 a "Flame Sensing Device Fault," a name Rinnai does not use for this code. A Q&A answer suggests unplugging the sensor so the heater runs again. In Rinnai's guide, unplugging the sensor is a test for a technician, covered below.

Which Rinnai models use code 79?

Rinnai's guide applies code 79 to its Non-SENSEI series only. That group covers the Value V models, the Luxury RL models, the RE and REP line, and older K-series units. The RU-series SENSEI manual's code table does not list 79 at all, so a 79 on a SENSEI unit calls for Rinnai's help line.

Group in Rinnai's guideExample modelsCode 79 listed?
Value (VC)V53De, V65i, V75e, V94i, V94XiYes, Non-SENSEI
Luxury (VB and VC)RL75i, RL75e, RL94i, RL94e, RLX94iYes, Non-SENSEI
RE and RE with PumpRE140i, RE199e, REP160i, REP199iYes, Non-SENSEI
KA, KB, KBD, KBP, KCMRC98i, RU98e, RUC98i, RUR98i, RUCS75iYes, Non-SENSEI
SENSEI RU and RURRU199i, RU160e, RUR199iNot in the RU manual's code table

Sources: Rinnai diagnostic guide, model list p. 2 and code 79 p. 62, May 2024; Rinnai RU-series manual 100000467(06), code table pp. 73-75, June 2020.

The model and serial label tells you which group you own. Rinnai's warranty documents give 1-800-621-9419 as its phone line.

How do I reset a Rinnai code 79?

There is no separate reset button for code 79. Rinnai's documents clear it by cycling power once the cause is dealt with. Resetting over water that is still there brings the code straight back, and it can hide a leak that is getting worse. Do the owner checks first.

  1. Turn off electrical power at the plug or breaker, close the gas valve below the unit, and close the water isolation valves. Rinnai's guide (p. 3) asks for all three before any diagnosis.
  2. Look under the heater and along the pipe connections for drips, wet insulation or mineral trails.
  3. If an RE or REP indoor unit sits on Rinnai's drain-pan leak kit, check the pan. Water there means something above it is leaking.
  4. Note the conditions. A code after rain, high humidity or a cold snap is a clue for the technician.
  5. If everything is dry, restore gas, water and power, and open a hot water tap.
  6. If 79 returns, shut the unit down again and call a technician. Do not remove the front cover or unplug the sensor.

The leak kit instructions, dated February 2022, test the float switch by lifting it until "79" appears, then clear it "by resetting power to the tankless water heater" (Rinnai document 100000789, p. 4). The diagnostic guide's third step, for a wet cabinet with no leak, is to dry the sensor and restart the heater.

Why does code 79 show up when nothing is leaking?

Condensation is Rinnai's own explanation for a code 79 with no leak. Where the air is very damp, moisture can collect at the bottom of the cabinet and wet the sensor. Rinnai calls these "nuisance code 79s" and published a shorter replacement sensing element to stop them.

That fix is Rinnai Technical Bulletin 101, "Code 79 Sensing Element", dated 2013. The sensing element is a screw held in a bracket at the bottom of the unit. The bulletin's procedure, for a qualified technician:

  1. Disconnect power and turn off the gas supply.
  2. Remove the four front panel screws and the panel. On indoor units, remove the controller bracket.
  3. Remove the factory sensing element screw from the sensor bracket.
  4. Fit the shorter, modified sensing element screw.
  5. Refit the bracket and panel, restore gas and power, and test the unit.

Q&A threads ranking for this code describe the same pattern: a 79 that shows up in rainy or damp conditions. That matches the bulletin. It does not rule out a slow leak, which is why Rinnai's guide checks the wiring, heat exchanger and internal pipes before blaming moisture.

Is it safe to unplug the leak sensor and keep using the heater?

No. In Rinnai's guide, unplugging the sensor is step four of a technician's test, done only after the cabinet has been checked and found dry. If the heater fires with the sensor unplugged, the guide says to replace the sensor and screw. It never treats running without the sensor as a repair.

The same diagnostic guide (May 2024) restricts its steps to trained and qualified professionals, warns of live tests near energized parts, and says not to use a heater if any part has been under water. On RE and REP units with the optional kit, the float switch also closes an internal water valve to stop further leakage, per Rinnai's leak kit instructions (February 2022). Bypassing the sensing circuit removes that protection.

Safety: water, gas and electricity together. Rinnai's guide says to turn off electrical power, gas and incoming water before any diagnosis, to keep clear of energized parts during live tests, and not to run the heater with the front panel off. Do not use the heater if any part has been under water. If you smell gas, leave the lights and switches alone and call the gas supplier from a neighbor's phone, or the fire department. Call a licensed technician for any water inside the cabinet, a code that returns after a power cycle, or a unit that was flooded. Source: Rinnai diagnostic guide, p. 3.

What does a code 79 repair cost?

It ranges from a service call to a heat exchanger. A condensation code may need only a visit and a sensor screw. A real internal leak can mean a heat exchanger, which HomeGuide lists at $600 to $1,300 in its August 2025 repair cost guide. Leak sensor part prices are not published in a form we could confirm.

RepairCostSource
Minimum service call-out fee$50 to $200HomeGuide, August 2025
Leak repair, any water heater$100 to $1,000HomeGuide, August 2025
Minor tankless repair$50 to $300HomeGuide, July 2025
Major tankless repair (heat exchanger, circuit board)$300 to $1,300HomeGuide, July 2025
Heat exchanger replacement, part plus labor$1,200 to $1,300HomeGuide, August 2025

Sources: HomeGuide, water heater repair cost, August 2025; HomeGuide, tankless water heater maintenance cost, July 2025.

HomeGuide's leak range covers tank heaters too, where a leak at a fitting or drain valve is often a small job. On a tankless unit the source decides the bill, so ask the technician to name the leaking part before quoting. The water heater repair prices guide lists other parts, and the leak repair guide covers which leaks are fixable.

Does Rinnai's warranty cover a code 79 leak?

A heat exchanger that leaks from a defect is covered for a long term on Rinnai's Non-SENSEI models, but labor coverage is short. The warranty also excludes damage from missing drain pans, freezing, condensate and poor water quality, so the cause the technician records matters.

SeriesHeat exchanger (residential)Other partsLabor
Value V53De, V65, V75, V9410 years5 years1 year
Luxury RL75, RL94, RLX9412 years5 years1 year, or 5 years if registered within 30 days

Sources: Rinnai HE Series (Value) warranty 100000656, May 2019; Rinnai HE+ Series (Luxury) warranty 100000657, May 2019; Rinnai Technical Bulletin 114, July 2015, for the 12-year Luxury term.

Both documents list "Absence of a drain pan under the appliance" and "Condensate damage" as improper installation, and "freeze damage" as improper maintenance. The Value document also excludes "Any damage caused by poor water quality." Coverage terms shrink in some cases: the Luxury heat exchanger drops to 5 years above a 160°F setting, and both series drop to 3 years in certain circulating-loop setups, per the Luxury and Value warranties (May 2019). Rinnai requires genuine parts and a qualified professional. For claims and servicers, see the Rinnai warranty and support guide.

Repair or replace after a code 79?

Repair when the cause is the sensor, wiring or condensation. Those are small jobs. The decision gets harder when the heat exchanger is leaking on a unit past its heat exchanger term, since that is the most expensive repair on a tankless heater.

FindingSuggested move
Damp cabinet, no leakDry it, ask about the TB-101 sensing element
Damaged sensor wiring or failed sensorRepair
Leaking internal pipe or fittingRepair
Leaking heat exchanger inside its warranty termWarranty claim
Leaking heat exchanger outside its termCompare a repair quote with a replacement quote

The tankless replacement cost guide covers what a new unit costs to install.

Frequently asked questions

Where is the leak sensor on a Rinnai tankless water heater?

At the bottom of the unit, inside the cabinet. Rinnai's Technical Bulletin 101 shows the sensing element as a screw held in a bracket, reached by removing the front panel. On indoor units the controller bracket also comes off. That is technician work.

Can I flush my Rinnai tankless water heater with vinegar?

Rinnai's RU-series manual (section 6.3, p. 80) specifies undiluted, food-grade white vinegar circulated by a pump, then a rinse. Other series have their own flushing steps, so use the manual for your model. Flushing treats scale; it does not fix a code 79.

What are the most common Rinnai error codes?

Airflow, ignition and flame faults come up most in owner searches. See the guides to Rinnai code 10, code 11 and code 12, or the Rinnai tankless error code guide.

Will code 79 stop my hot water?

Expect it to. Owners report losing hot water when 79 appears, and on RE and REP units with Rinnai's leak kit, the float switch closes an internal water valve by design. Treat the code as a reason to shut the unit down and check it.

Sources

Independent Research

Check a quote against a published range

Published ranges for tank, tankless and heat pump replacement, the failures that justify a repair, and the ones that do not. Sourced, dated, and free to read.